Specification
126RT includes all the features of 126WT with the additional benefit of wireless connectivity, which saves some annoying installing troubles.
Features
l Open Therm protocol supported
l Large LCD display, easy to read
l 7 days programmable, 48 set points per day
l Frost protection temperature function
l Auto/Party/Off/Holiday work mode optional
l Hysteresis value adjustable
Transmitter technical data
Power supply 2x1.5V AAA -Alkaline batteries, with low battery indication
Relay output Max 2A @ 30V DC/0.25A @230V AC
Temperature setting range 5℃-35℃
Temperature sensor Built-in
Size: 138x86x23mm
Color: White/Black
Receiver technical data
Model HRT-101C
Power supply 230V AC+ 10%, 50Hz
Power consumption 1.2W
Radio frequency 868MHz or 433MHz (up to 100m in open air)
Relay output Max 2A @ 30V DC/0.25A @230V AC
Size 86x86x35mm
Wiring Connecting to gas boiler with 6 wires cable
|